Materials home :: Autoclaves :: Ambient Testing :: Large Scale Vessel

Ambient Pressure Corrosion Testing

 

Ambient pressure corrosion testing can be undertaken where real-time corrosion rates can be measured using computer cotrolled LPR (Linear Polarisation Resistance) and EIS (Electrochemical Impedance Spectroscopy) corrosion monitoriing equipment.

Full Ring Test being set up

Full Ring Testing
Facilities exist that enable full ring testing of pipeline sections, up to 36" diameter, including butt welded and seam welded sections . This allows evaluation of:
* Hydrogen induced cracking (HIC)
* Sulphide Stress Corrosion Cracking (SSCC)
* Stress Oriented Hydrogen Induced Cracking (SOHIC)

 

 

Materials home :: Autoclaves :: Ambient Testing :: Large Scale Vessel


©Advantica Ltd 2008